ISO INTERNATIONAL STANDARD 7240-27 Second edition 2018-05 Fire detection and alarm systems Part 27: Point type fire detectors using a smoke sensor in combination with a carbon monoxide sensor and, optionally, one or more heat sensors Systemes de détection et d'alarme d'incendie- Partie 27: Deétecteurs ponctuels d'incendie utilisant un capteur de fumée en combinaison avec un capteur de monoxyde de carbone (co) et, optionnellement, un ou plusieurs capteurs de chaleur Reference number IS0 7240-27:2018(E) @ IS0 2018 IS0 7240-27:2018(E) COPYRIGHTPROTECTED DOCUMENT @IS02018 All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either IsO at the address below or ISo's member body in the country of the requester. ISO copyright office CP 40i : Ch. de Blandonnet 8 CH-1214 Vernier, Geneva Phone:+4122 749 0111 Fax: +41 22 749 09 47 Email: copyright@iso.org Website: www.iso.org Published in Switzerland ii @ IS0 2018 - All rights reserved IS0 7240-27:2018(E) Contents Page Foreword ..vii Introduction. .viii 1 Scope. 2 Normative references 3 Terms, definitions and symbols. ..2 4 General requirements. .2 4.1 Compliance. 2 4.2 Response threshold value of detectors using scattered or transmitted light. 2 4.3 Individual alarm indication. .2 4.4 Connection ofancillarydevices .3 4.5 Monitoring of detachable detectors. 3 4.6 Manufacturer's adjustments.. 4.7 On-site adjustment of response behaviour 3 4.8 Protection against the ingress of foreign bodies 3 4.9 Rate-sensitiveCOresponsebehaviour 3 4.10 Smoke response to slowly developing fires .4 4.11 Requirements for software controlled detectors 4 4.11.1 General .4 4.11.2 Software design ..4 4.11.3 Storage of programs and data .4 5 Tests .5 5.1 General .5 5.1.1 Atmosphericconditionsfortests 5 5.1.2 Operating conditions for tests. .5 5.1.3 Mounting arrangement... .5 5.1.4 Tolerances. 5.1.5 Measurement of smoke response threshold value 5 5.1.6 Measurement of cO response threshold value .6 5.1.7 Measurement of heat sensor response value. .6 5.1.8 Provisionfortests ..7 5.1.9 Test schedule .8 5.1.10 Test report. 8 5.2 Repeatability of smoke response .8 5.2.1 Object of the test. .8 5.2.2 Test procedure 5.2.3 Requirements 8 5.3 Repeatability of cO response .8 5.3.1 Object of the test. ..8 5.3.2 Test procedure 5.3.3 Requirements. ..10 5.4 Directional dependence of smoke response .10 5.4.1 Object of the test .10 5.4.2 Test procedure .10 5.4.3 Requirements .10 5.5 Directional dependence of CO response ..10 5.5.1 Object of the test .10 5.5.2 Test procedure .10 5.5.3 Reguirements .10 5.6 Directional dependence of heat response (optional function) ..11 5.6.1 Object of the test ..11 5.6.2 Test procedure .11 5.6.3 Requirements 11 @IS02018-All rightsreserved ili

.pdf文档 ISO 7240-27 2018 Fire detection and alarm systems — Part 27 Point type fire detectors using a smoke sensor in combination with a carbon monoxide sensor and, optionally, one or more heat sensors

文档预览
中文文档 69 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共69页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
ISO 7240-27 2018 Fire detection and alarm systems — Part 27  Point type fire detectors using a smoke sensor in combination with a carbon monoxide sensor and, optionally, one or more heat sensors 第 1 页 ISO 7240-27 2018 Fire detection and alarm systems — Part 27  Point type fire detectors using a smoke sensor in combination with a carbon monoxide sensor and, optionally, one or more heat sensors 第 2 页 ISO 7240-27 2018 Fire detection and alarm systems — Part 27  Point type fire detectors using a smoke sensor in combination with a carbon monoxide sensor and, optionally, one or more heat sensors 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2024-08-10 15:14:39上传分享
友情链接
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。