ISO/TR TECHNICAL REPORT 24679-3 First edition 2015-08-01 Fire safety engineering Performance of structure in fire - Part 3: Example of an open car park Ingenierie de la sécurite incendie - Performance des structures en situation dincendie- Partie 3: Exemple d'un parking aérien largement ventilé Reference number IS0/TR24679-3:2015(E) SO International Organization for Standardization @ IS0 2015 dardization 5956617 IS0/TR24679-3:2015(E) COPYRIGHTPROTECTEDDOCUMENT IS02015,PublishedinSwitzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISO's member body in the country of the requester. ISO copyrightoffice Ch. de Blandonnet 8 . CP 401 CH-1214 Vernier, Geneva, Switzerland Tel. +41 22 749 01 11 Fax +41 22 749 09 47 [email protected] www.iso.org Intenationaibr PrganizationforStandardization etworking permitted without license from IHS IS0/TR 24679-3:2015(E) Contents Page Foreword ..iv Introduction. ..V 1 Scope. .1 2 Normative references ..1 3 Terms and definitions ..2 4 Design strategy for fire safety of structures. ..2 5 Quantification of the performance of structures in fire .2 5.1 Fire performance of structures - Design process. .2 5.2 Step 1: Scope of the project for fire safety of structures .2 5.2.1 Built environment characteristics .2 5.2.2 Fuel loads .4 5.2.3 Mechanical actions. ..5 5.3 Step 2: Identify objectives, functional requirements, and performance criteria for fire safety of structures .5 5.4 Step 3:Trialdesignplan forfire safetyof structures. .6 5.5 Step 4: Design fire scenarios and design fires. .8 5.5.1 Design fire scenarios .8 5.5.2 Design fires (thermal actions) .10 5.6 Step 5: Thermal response of the structure .13 5.7 Step 6: Mechanical response of the structure .17 5.8 Step 7: Assessment against the fire safety objectives .22 5.9 Documentation of the design for fire safety of structures 22 5.10 Factors and influences to be considered in the quantification process ..22 6 Guidance on use of engineering methods ..22 Annex A (informative) Analysis of structural behaviour of open car parks ..23 Annex B (informative) Views and plans of the open car park .38 Bibliography .41 iii dardization5956617

.pdf文档 ISO TR 24679-3 2015 Fire safety engineering — Performance of structure in fire — Part 3 Example of an open car park

文档预览
中文文档 48 页 50 下载 1000 浏览 0 评论 309 收藏 3.0分
温馨提示:本文档共48页,可预览 3 页,如浏览全部内容或当前文档出现乱码,可开通会员下载原始文档
ISO TR 24679-3 2015 Fire safety engineering — Performance of structure in fire — Part 3  Example of an open car park 第 1 页 ISO TR 24679-3 2015 Fire safety engineering — Performance of structure in fire — Part 3  Example of an open car park 第 2 页 ISO TR 24679-3 2015 Fire safety engineering — Performance of structure in fire — Part 3  Example of an open car park 第 3 页
下载文档到电脑,方便使用
本文档由 人生无常 于 2024-08-26 08:29:45上传分享
站内资源均来自网友分享或网络收集整理,若无意中侵犯到您的权利,敬请联系我们微信(点击查看客服),我们将及时删除相关资源。